A.8.14ISO 27001:2022 Annex A

Redundancy of information processing facilities

ISO/IEC 27002:2022 attributes

Control type
Preventive
Security properties
Availability
Cybersecurity concept
Protect
Operational capability
Asset management · Continuity
Security domain
Protection · Resilience

Attribute tags as published in ISO/IEC 27002:2022, compiled from public listings — confirm against your licensed copy.

Plain-language summary

Building enough duplication into systems, networks, power and service providers that the failure of one component does not take down a service the business needs, with the level of redundancy set by agreed availability requirements rather than habit.

What the clause is really asking

Backup gets you back after a failure; redundancy keeps you running through it. The control asks you to identify the availability requirements for business services and the information systems behind them, then design and implement enough redundancy to meet them: duplicate components such as servers, storage, power supplies and network links; more than one supplier for critical connectivity; separate locations where the requirement justifies it; and failover that has been tested. Where redundancy cannot be built, other measures, usually backup and a recovery plan, must fill the gap. Redundancy brings its own risks: replicated systems copy corruption and ransomware encryption as faithfully as good data, and failover that is never tested often fails when needed. In South Africa, load-shedding and grid instability make power redundancy a practical question — UPS, generator or inverter capacity sized for how long systems must keep running — and fibre outages make a second internet link on a different route or technology more than a luxury. For cloud services, check that availability zones and service levels match your requirement.

What auditors look for

Auditors ask for the availability requirements of critical services and then for the design that meets them, looking for single points of failure: one internet link, one firewall, one server running the ERP, one power feed to the server room. They ask when failover was last tested, what happened and whether it was recorded. They check UPS and generator maintenance records and how long systems can run on battery. For cloud services they compare the provider's service levels and zone design with your stated requirement. The hard question: if your main internet link failed right now, what would stop, and for how long?

Typical evidence

Availability requirements per critical service, typically from the business impact analysis; architecture diagrams showing redundant components; single-point-of-failure analysis with decisions; failover test records with outcomes; UPS, generator and inverter capacity and maintenance records; contracts for secondary connectivity; cloud service-level agreements and zone or region configuration; records of incidents involving redundant components.

How to comply — recommendations

Take the critical services from your business impact analysis and write down how long each can be unavailable. For each, draw a simple diagram from user to data and mark every single point of failure: power, internet link, firewall, switch, server, storage, key supplier. Fix the ones that break the requirement — a second internet link on a different technology, a UPS or inverter sized for your outage profile, a second firewall in high-availability mode, cloud workloads across more than one zone — and accept the rest in writing. Test failover at least annually, for example by disconnecting the primary link out of hours, and record the result. Maintain UPS batteries and generators to a schedule.

Common nonconformities

Availability requirements never defined; single points of failure in critical services not identified or formally accepted; failover never tested, or tested without records; UPS batteries unmaintained or runtime unknown; a single internet link for a business that cannot operate offline; redundant links sharing the same physical route; cloud workloads in one zone despite high availability needs.

Related clauses

ISO/IEC 27002:2022 8.14 (guidance); ISO 27001 6.1.3, 8.1; Annex A 5.29 (information security during disruption), 5.30 (ICT readiness for business continuity), 7.11 (supporting utilities), 8.6 (capacity), 8.13 (backup); NIST CSF 2.0 PR.IR (technology infrastructure resilience); ISO 22301; ISO 9001 7.1.3 (infrastructure).

Resources for this clause

Get the free ISO 27001 Annex A — 93 Controls Quick Reference (A3 PDF)

Free, instant download. We'll only email you the occasional practical quality update — no spam, unsubscribe anytime.

Qlause provides interpretive guidance only and is not a substitute for the standard. Refer to your licensed copy of the relevant standard for the authoritative text.

Certification & implementation

Working on a certification or system implementation project?

Implementing ISO 9001, moving to the 2026 edition, getting ready for a certification audit, or stuck on a clause that doesn't seem to fit your operation? Tell us where you are and where you're stuck. We'll look at it and suggest a practical next step, or connect you with people we trust who can help.