A.7.8ISO 27001:2022 Annex A

Equipment siting and protection

ISO/IEC 27002:2022 attributes

Control type
Preventive
Security properties
Confidentiality · Integrity · Availability
Cybersecurity concept
Protect
Operational capability
Asset management · Physical security
Security domain
Protection

Attribute tags as published in ISO/IEC 27002:2022, compiled from public listings — confirm against your licensed copy.

Plain-language summary

Placing and protecting equipment so it is safe from physical and environmental harm and from unauthorised access or viewing — servers, network gear, shop-floor PCs and printers sited where heat, dust, water, impact and prying eyes cannot reach them.

What the clause is really asking

Where equipment sits decides much of its risk, and this control asks you to choose locations and protection for it with security in mind. The considerations are physical and environmental: keeping equipment away from heat, dust, water, vibration, chemicals and electrical interference; controlling temperature and humidity; protecting against theft and tampering; positioning screens and printers so sensitive information cannot be seen by people who should not see it; keeping food and drink away from critical equipment; and lightning or surge protection where needed. The misunderstanding is that only the data centre counts. In manufacturing the harsh environment is on the production floor: network switches in cabinets beside a moulding line, PCs exposed to dust and heat, routers mounted where a forklift can hit them, and machine controllers holding programmes and recipes. These need enclosures, cooling, guards and locks as much as servers do. An ISO 9001 practitioner will recognise the link with infrastructure and the environment for operating processes; the engineers who site production equipment should be involved.

What auditors look for

Auditors visit the server room, network cabinets and a sample of equipment on the shop floor and in offices. They look for heat, dust, water and impact risks, check temperature and humidity monitoring, and see whether cabinets are locked. They note screens visible from public areas, printers in corridors and equipment under pipes. They ask how the siting of new equipment is approved and check environmental alerts. The hard question: what is the temperature in your server room right now, and who gets told if it rises?

Typical evidence

Equipment siting standard; inventory showing location of critical equipment; temperature and humidity monitoring with alert settings and logs; locked cabinets and enclosures; impact protection for floor-mounted equipment; surge protection; inspection records for server and network rooms; approval records for new installations.

How to comply — recommendations

Write a half-page equipment siting standard covering temperature, dust, water, impact, locking and screen visibility, and apply it to every new installation. Survey what you have: the server room, each network cabinet and a sample of shop-floor PCs. Fix the worst first: locked, ventilated enclosures on the floor, barriers or bollards where forklifts operate, and temperature sensors in the server room that alert a person. Turn screens away from windows and reception. Add equipment siting to the change process so engineering and IT agree before anything is installed. Inspect quarterly alongside the facilities checks.

Common nonconformities

Server room without temperature monitoring or alerts; equipment under water pipes or standing on the floor; network cabinets unlocked or exposed to dust and impact on the production floor; screens showing sensitive information visible to visitors; food and drink beside critical equipment; no surge protection; new equipment installed without any siting review.

Related clauses

ISO/IEC 27002:2022 7.8 (guidance); ISO 27001 8.1; Annex A 5.9 (asset inventory), 7.5, 7.11 (utilities), 7.12 (cabling), 7.13 (maintenance); NIST CSF 2.0 PR.IR (technology infrastructure resilience), PR.AA (physical access); ISO 9001 7.1.3 (infrastructure), 7.1.4 (environment for operation of processes).

Resources for this clause

Get the free ISO 27001 Annex A — 93 Controls Quick Reference (A3 PDF)

Free, instant download. We'll only email you the occasional practical quality update — no spam, unsubscribe anytime.

Qlause provides interpretive guidance only and is not a substitute for the standard. Refer to your licensed copy of the relevant standard for the authoritative text.

Certification & implementation

Working on a certification or system implementation project?

Implementing ISO 9001, moving to the 2026 edition, getting ready for a certification audit, or stuck on a clause that doesn't seem to fit your operation? Tell us where you are and where you're stuck. We'll look at it and suggest a practical next step, or connect you with people we trust who can help.