A.7.5ISO 27001:2022 Annex A

Protecting against physical and environmental threats

ISO/IEC 27002:2022 attributes

Control type
Preventive
Security properties
Confidentiality · Integrity · Availability
Cybersecurity concept
Protect
Operational capability
Physical security
Security domain
Protection

Attribute tags as published in ISO/IEC 27002:2022, compiled from public listings — confirm against your licensed copy.

Plain-language summary

Designing protection against the physical and environmental events that can destroy or disable information assets — fire, flood, lightning, storms, power surges, civil unrest, theft and accidents — based on an assessment of what your sites actually face.

What the clause is really asking

A server room flooded by a burst pipe or a plant data centre lost to fire is an information security incident as much as a hack, and this control asks you to identify the physical and environmental threats to your sites and build protection against them. Start with a risk assessment for each location: natural hazards such as flooding, lightning, storms and fire; human-made threats such as explosion, civil unrest, theft and vandalism; and nearby hazards such as a flammable store or a river. Then protect proportionately: fire detection and suppression suited to electronic equipment, water detection, lightning and surge protection, equipment raised off the floor, and specialist advice where the risk warrants it. The misunderstanding is that the landlord or the insurer has it covered. In South Africa the list is concrete: recent floods in KwaZulu-Natal and the Eastern Cape, the July 2021 unrest in which warehouses were looted, frequent lightning, and surges when power returns after outages. Your ISO 45001 and ISO 14001 emergency preparedness already identifies fire and flood scenarios; extend it to information assets.

What auditors look for

Auditors ask for the physical and environmental risk assessment for each site and check that it names the threats that apply rather than a generic list. They walk the server and network rooms looking for water pipes overhead, equipment on the floor, combustible storage, missing fire detection and the type of extinguisher. They ask for fire detection and suppression service records, surge and lightning protection, and whether water sensors alert anyone. They compare the emergency preparedness plan with the information assets it should cover. The hard question: what happens to the servers if the sprinklers go off or the river floods?

Typical evidence

Physical and environmental risk assessment per site; fire detection and suppression design and service records; water detection and alerting; surge and lightning protection inspection records; emergency preparedness and response plan covering information assets; insurer survey and recommendations; housekeeping inspections of server and network rooms; drill and test records.

How to comply — recommendations

Add information assets to the site emergency risk assessment you already keep for ISO 45001 or your insurer, and score fire, flood, lightning, surge, unrest and theft for the server room, network cabinets and records stores. Move equipment off the floor and away from pipes, keep combustibles out of server rooms, fit smoke detection and an extinguisher suited to electrical fires, and add water sensors that alert a person. Install surge protection at the distribution board and on critical racks. For high-risk sites, keep a copy of critical data at another location. Include the server room in fire drills and inspections.

Common nonconformities

No assessment of physical or environmental threats; server room below water pipes or at flood level; combustible material stored with equipment; no fire detection in the server room, or the wrong extinguisher type; no surge or lightning protection; emergency plan ignores information assets; fire suppression not serviced; all copies of critical data held at one site.

Related clauses

ISO/IEC 27002:2022 7.5 (guidance); ISO 27001 6.1.2; Annex A 7.8 (equipment siting), 7.11 (supporting utilities), 5.29–5.30 (disruption and ICT continuity), 8.13 (backup), 8.14 (redundancy); NIST CSF 2.0 PR.IR (technology infrastructure resilience); ISO 45001 8.2 and ISO 14001 8.2 (emergency preparedness).

Resources for this clause

Get the free ISO 27001 Annex A — 93 Controls Quick Reference (A3 PDF)

Free, instant download. We'll only email you the occasional practical quality update — no spam, unsubscribe anytime.

Qlause provides interpretive guidance only and is not a substitute for the standard. Refer to your licensed copy of the relevant standard for the authoritative text.

Certification & implementation

Working on a certification or system implementation project?

Implementing ISO 9001, moving to the 2026 edition, getting ready for a certification audit, or stuck on a clause that doesn't seem to fit your operation? Tell us where you are and where you're stuck. We'll look at it and suggest a practical next step, or connect you with people we trust who can help.