PublishedISO 9001:2026 published 16 Sept 2026 · 2015 certificates must transition by 30 Sept 2029What changed →
Internal Auditor course (ISO 19011:2026):free until 31 Oct · then $59 for three monthsStart free now →
← Back to Clause Explorer
A.7.1ISO 27001:2022 Annex A

Physical security perimeters

ISO/IEC 27002:2022 attributes

Control type
Preventive
Security properties
Confidentiality · Integrity · Availability
Cybersecurity concept
Protect
Operational capability
Physical security
Security domain
Protection

Attribute tags as published in ISO/IEC 27002:2022, compiled from public listings — confirm against your licensed copy.

Plain-language summary

Drawing clear boundaries around the places that hold information and the equipment that handles it — site, building, secure rooms — and making each boundary strong enough for what sits inside, with no gaps through windows, ceilings or doors left open.

What the clause is really asking

Logical controls mean little if someone can walk in and carry the server out, so this control asks you to decide where the boundaries around your information and its supporting equipment run, and to make each one effective. In practice that means layers: the site boundary, the building shell, and inner zones such as the server room, the HR records store or the engineering office holding customer drawings. The strength of each perimeter should follow the risk assessment for what it protects, and it must be continuous: solid walls and doors, locks and alarms on external doors and reachable windows, fire exits that alarm when opened, and no false ceiling or raised floor that bypasses a locked room. The misunderstanding is applying office thinking to a manufacturing site; plants and warehouses have roller doors open for hours during dispatch, contractor gates and network cabinets out on the production floor, and those are the real gaps. If you run ISO 45001 or keep a site security plan for your insurer, the fencing, gatehouse and zone drawings already exist.

What auditors look for

Auditors ask for a site plan showing the perimeters and zones, then walk them. They check that server room walls run slab to slab, try doors that should be locked, look for propped-open fire exits and reachable windows, and follow the route a delivery driver or contractor takes. On a manufacturing site they watch dispatch doors during loading, the gatehouse process and network cabinets on the floor. They compare the zones with the risk assessment and ask how perimeter strength was decided. The hard question: show me every way into the server room, including over the ceiling.

Typical evidence

Site and building plans marking perimeters and security zones; physical security risk assessment; perimeter inspection checklists and records; alarm and door-contact configuration for external doors and fire exits; maintenance records for fences, gates and locks; insurer or security consultant survey reports; log of perimeter defects and repairs.

How to comply — recommendations

Mark up a site plan with three or four zones: public, general working areas, restricted (offices with sensitive data, production control rooms) and secure (server room, records store). For each zone note the perimeter: fence, wall, door type, lock, alarm. Walk it with facilities and the security contractor and log every gap, including ceilings, windows and dispatch doors. Fix the cheap ones first: door closers, alarms on fire exits, a locked cage around floor network cabinets. Add a quarterly perimeter inspection to the facilities checklist you already run for safety, and update the plan whenever buildings or layouts change.

Common nonconformities

No defined perimeters or zones; server room reachable over a false ceiling or through a partition wall; fire exits propped open without alarm; ground-floor windows unsecured; dispatch doors left open and unsupervised; network cabinets on the production floor unlocked; perimeter never inspected; site plan out of date after building changes.

Related clauses

ISO/IEC 27002:2022 7.1 (guidance); ISO 27001 6.1.2 (risk assessment), 8.1; Annex A 7.2 (physical entry), 7.3, 7.4, 7.5, 5.9 (asset inventory); NIST CSF 2.0 PR.AA (identity management, authentication and access control, including physical access); ISO 9001 7.1.3 (infrastructure).

Resources for this clause

Get the free ISO 27001 Annex A — 93 Controls Quick Reference (A3 PDF)

Free, instant download. We'll only email you the occasional practical quality update — no spam, unsubscribe anytime.

Qlause provides interpretive guidance only and is not a substitute for the standard. Refer to your licensed copy of the relevant standard for the authoritative text.

Certification & implementation

Working on a certification or system implementation project?

Implementing ISO 9001, moving to the 2026 edition, getting ready for a certification audit, or stuck on a clause that doesn't seem to fit your operation? Tell us where you are and where you're stuck. We'll look at it and suggest a practical next step, or connect you with people we trust who can help.

Email hello@qlause.app

No sales pitch, no obligation — we read every message.